Watch for
What can go wrong with an aluminum roof?
Dents, heat movement, metal contact and fasteners are the usual problems, and each has a fix.
Dents. Aluminum is softer. Walking on it and hail can mark it. That is a look issue more than a leak issue, but it is worth knowing.
Metal contact. Different metals touching can cause corrosion where water sits between them. McElroy's warranty excludes damage from runoff from copper, lead, nickel and stainless steel touching or draining on its panels. Ask your roofer how trim, fasteners and flashing metals are kept apart from the panels.
Fasteners. Florida Roof magazine quotes experts who say to use stainless steel fasteners on the coast, even for concealed-fastener roofs, and one cites FEMA guidance for full 300-series stainless within 3,000 feet of salt water. That quote is about fasteners, not panels. Ask what the fasteners are and why.
Thickness. Residential roofs typically use .032 or .030 inch aluminum, per Sheffield. Florida Roof magazine quotes a consultant who says the go-to on the coast is .040 or .050 inch. The 2010 Florida Building Code text quoted by DBPR sets 0.024 inch as the minimum for roll-formed aluminum panels. Ask for the thickness in writing.
Wind rating. A Boral representative quoted in Florida Roof magazine says warranty and wind performance for aluminum, copper and zinc may be lower than other materials. Whatever the metal, ask for the Florida Product Approval for the exact panel, deck and fastening.
A note on what Coastline installs
Coastline installs 24-gauge standing seam and 5V crimp metal roofs. If your home is close to salt water, tell us how close in your inspection request. We will look at what is on the roof, give you a written photo report and answer plainly.